APPLICATION
Prior the application of the Sikagard® Hygienic Coating System the priming coat if used must have cured for the appropriate Waiting Time / Overcoating (please refer to the PDS of the appropriate primer). Damageable areas (handrails etc.) have to be protected with tape or plastic wrapping.
Sika® Reemat Lite is applied in combination with Sikagard® Hygienic Coatings.
Apply first coat of Sikagard® Hygienic Coating with a consumption rate according to the PDS of the relevant hygienic coating system. Work only so far in advance that the material stays liquid.
Roll out the Sika® Reemat Lite and ensure that there are no bubbles or creases. Overlapping of Sika® Reemat Lite must be minimum 5 cm and ensure overlaps are sufficiently wet to bond.
The roller may require only a little extra material to remain wet but no further significant material needs to be added at this stage.
After the coat as had the appropriate Waiting Time / Overcoating contine with subsequent coats as per the relevant Sikagard® Hygienic Coating Datasheet / System Datasheet.