Sika Boom® P
Sika Boom® P is a 1-component, fast curing polyurethane foam made for easy application with plastic nozzle
- 1-Component
- Easy application with nozzle
- High expanding rate
- Fast curing
- Very good thermal insulation
- Effective sound dampening
- HFC-free
Usage
Sika Boom® P is designed for fixing, insulating and filling connection joints around windows and door frames, pipe entries, air-conditioning vents and electrical equipment. Sika Boom® S allows insulation against noise, cold and draughts after a single applicatioAdvantages
- 1-Component
- Easy application with nozzle
- High expanding rate
- Fast curing
- Very good thermal insulation
- Effective sound dampening
- HFC-free
Packaging
Sika Boom® P shall be stored in an upright position, in dry conditions, protected from direct sunlight and at temperatures between +5 °C and +25 °C.
Colour
Light yellow
Product Details
Composition
Polyurethane
Shelf life
Sika Boom® P has a shelf life of 15 months from the date of production, if stored properly in undamaged, original, sealed packaging, and if the stor-
age conditions are met. Opened cans of Sika Boom® P must be used within 4 weeks
Storage conditions
Sika Boom® P shall be stored in an upright position, in dry conditions, protected from direct sunlight and at temperatures between +5 °C and +25 °C.
Density
0,022 ± 3 kg/dm3
Compressive strength
0,03 MPa
Dimensional stability
± 10%.
Resistance to fire
B3
Temperature resistance
Aprox. 0,036 W/mK.
Water absorption
Max. 1% volume
Service temperature
-40 °C to +80 °C.
Application
Ambient air temperature
+10 °C min. / +30 °C max.
Relative air humidity
30 % min. / 95 % max.
Substrate temperature
+10 °C min. / +30 °C max.
Curing time
Sika Boom® P is fully cured after 12 h
Cutting time
Aprox. 30 minutes
Tack free time
5 to 10 minutes
Consumption
Max. aprox. 45 dm3
APPLICATION INSTRUCTIONS
For the application of Sika Boom® P all generally accepted rules of building and construction apply.
SUBSTRATE PREPARATION
The substrate must be clean, sound and homogeneous, free from oils, grease, dust and loose or friable particles. Paint, cement laitance and other poorly adhering contaminants must be removed. Sika Boom® P adheres without primers and/or activators. Pre-dampen the substrate with clean water, this ensures that the foam cures properly and also prevents secondary foam expansion.
CLEANING OF EQUIPMENT
Clean all tools and application equipment immediately with Sika Boom®-Cleaner and/or Sika® Remover-208. Once cured, residual material can only be removed mechanically.