SikaBond®-110 Multi Floor
SikaBond®-110 Multi Floor is a 1-component, solvent-free general-purpose dispersion adhesive.
- Very easily spread
- Low consumption / high coverage
- Suitable for wet bonding
- Suitable for use with underfloor heating
- Suitable for use with castor-chairs
- Suitable for shampooing
Usage
SikaBond®-110 Multi Floor is designed for full surface bonding of mentioned below floor coverings on absorbent substrates in interior areas:Carpets with PVC, PU or filler-free backingPVC and cushioned vinyl (CV) floor coveringsNatural fibre coverings with backingImpact sound insulation underlaysSingle or multilayer needle feltingCorkment and cork linoleumWoven fabricsLinoleum coverings
Advantages
- Very easily spread
- Low consumption / high coverage
- Suitable for wet bonding
- Suitable for use with underfloor heating
- Suitable for use with castor-chairs
- Suitable for shampooing
Packaging
1 kg, 6 kg, 14 kg plastic pail
Colour
Beige
Product Details
SUSTAINABILITY
- EMICODE EC1PLUS
Composition
1-Component dispersion
Shelf life
SikaBond®-110 Multi Floor has a shelf life of 12 months from the date of production, if it is stored properly in undamaged, original, sealed packaging, and if the storage conditions are met.
Storage conditions
SikaBond®-110 Multi Floor shall be stored in dry conditions, protected from direct sunlight and at temperatures between +5 °C and +25 °C.
Density
~1.40 kg/l | (ISO 1183-1) |
Consistency
Middle viscous, spreads very easily
Service temperature
+5 °C to +35 °C
Application
Ambient air temperature
+15 °C to +35 °C
Relative air humidity
40 % to 65 %
Substrate temperature
During laying and until SikaBond®-110 Multi Floor has fully cured, the substrate and ambient temperatures shall be between +15 °C and +35 °C without and between +20 °C and +35 °C with underfloor heating.
Substrate moisture content
Permissible substrate moisture content without underfloor heating:
- 2.0 % CM for cement screeds.
- 0.5 % CM for anhydrite screeds.
- 3–12 % CM for magnesia flooring (depending on the organic content).
Permissible substrate moisture content for use with underfloor heating:
- 1.8 % CM for cement screeds.
- 0.3 % CM for anhydrite screeds.
- 3–12 % CM for magnesia flooring (depending on the organic content).
Note: For all moisture contents and the quality of the substrates and surfaces always follow the guidelines of the soft floor manufacturer.
Curing time
~24 h (final strength after ~72 h)
Skin time / laying Time
~15–30 min (depending on laying method)
Flash-off time
~5–15 min
Consumption
~300 g/m2 | Trowel A1 | PVC floor coverings with even backing, CV floor coverings |
~350 g/m2 | Trowel A2 | PVC floor coverings with structured backing, carpets with PVC backing, insulation underlays |
~370 g/m2 | Trowel B1 | Linoleum coverings |
370–500 g/m2 | Trowel B1 / B2 | Textile floor coverings, needle felting |
Note: Trowel A1, A2, B1, B2: trowels according to "Technische Kommission Bauklebstoffe" (TKB), Germany.
APPLICATION INSTRUCTIONS
For the application of SikaBond®-110 Multi Floor all standard construction guidelines and relevant valid data sheets apply.
SUBSTRATE PREPARATION
- The substrate must be clean, dry, sound and homogeneous, free from oils, grease, dust and loose or friable particles. Paint, cement laitance and other poorly adhering contaminants must be removed.
- SikaBond®-110 Multi Floor adheres without primers and/or activators.
- The subfloor must meet the requirements of national standards, must have good compression and tensile strength and has to be even.
- Defective subfloors shall be treated by taking appropriate measures e.g. grinding, milling, vacuuming or priming.
- To produce an absorbent, even subfloor, a cement- based leveling compound shall be used, e.g. Sika® Level-200 or -300 Extra. For appropriate layer thicknesses refer to the relevant valid data sheets.
- Mastic asphalt and other non-absorbent subfloors may require specific self-leveling compound layer thicknesses. For appropriate layer thicknesses refer to the relevant valid data sheets.
- Concrete and/or cement screeds must be ground and thoroughly cleaned with an industrial vacuum.
- When installing floor covering with underfloor heating, existing measuring points have to be checked regarding the moisture content of the subfloor.
CLEANING OF EQUIPMENT
Clean all tools and application equipment immediately after use with water or Sika® TopClean T. Once cured, residual material can only be removed mechanically.